Sooner or later a customer, a lab or an old piece of software asks for a barcode you have never heard of: Code 93, MSI, Codabar, "2 of 5" or Pharmacode. These are linear symbologies that predate today's defaults, and each one is still in use somewhere.
This guide explains what each one encodes, where you are likely to meet it, and what to use instead when the choice is yours. It does not cover Code 39 and Code 128, which have their own comparison.
The short version
| Symbology | Encodes | Where you may meet it | For new labels |
|---|---|---|---|
| Code 93 | Uppercase letters, digits, some symbols; full ASCII with shift characters | Logistics and legacy label formats | Code 128 |
| MSI (Plessey) | Digits only | Older retail inventory systems | Code 128 |
| Codabar | Digits, six symbols, start/stop letters A–D | Libraries, medical, older shipping and photo-finishing systems | Code 128 |
| Interleaved 2 of 5 | Digits only, in pairs | Cartons (as ITF-14), older warehouse systems | ITF-14 for cartons, otherwise Code 128 |
| Pharmacode | One whole number, 3 to 131070 | Pharmaceutical packaging lines | Match the packaging line's requirement |
Code 93
Code 93 was developed in 1982 as a very dense symbology that combines features of Code 39 Full ASCII and GS1-128, according to Seagull Scientific's symbology guide. Each character is three bars and three spaces in nine modules. It encodes digits, uppercase letters, a few symbols and space, and four shift characters reach the rest of the 128 ASCII characters.
It always carries two mod-47 check characters just before the stop character. That makes it safer than basic Code 39, but Code 128 offers a similar mix of density and error checking, is more widely supported. Scandit describes Code 93 as mostly used in logistics; you will mostly meet it because someone's existing format already uses it.
MSI (MSI Plessey)
MSI is numeric only, and the data can be any length. DataFlex's documentation describes it as based on the older Plessey code and used mainly for inventory management in retail. Its main quirk is the check digit. Software typically offers none, mod 10, mod 10 plus mod 10, mod 11, or mod 11 plus mod 10.
That matters because the scanner or software on the other end has to expect the same scheme. If a legacy inventory system asks for MSI, ask which check digit option it uses before you print anything. Otherwise an extra digit may show up in your data, or labels may be rejected.
Codabar
Codabar encodes the digits and six symbols (- $ : / . +). Its letters A through D are used only as start and stop characters, and the two do not have to match, per Seagull Scientific. The same page lists other names, including USD 4, 2 of 7 and, in Japan, NW-7, and says an optional mod-16 check digit exists.
Codabar was promoted for libraries, shipping, photo finishing and medical uses and has been giving way to other symbologies since the 1980s. If an old library, medical or photo-finishing system uses it, you may still need to match it. Our Codabar generator makes Codabar: type digits and it adds start and stop letters A and A, or type your own such as B or C if the system expects them. For example, A40156B is a valid message.
Interleaved 2 of 5 and ITF-14
Interleaved 2 of 5 (ITF) encodes digits only. It is specified in ISO/IEC 16390, and it needs an even number of digits: when the count is odd (before any check digit), a leading zero is added, so 12345 is encoded as 012345.
Seagull Scientific notes that it is often chosen over Code 39 for numeric data because it needs about half the space, but that its built-in data security is lower, so it recommends a mod-10 check digit or a fixed length. The same page points out that bearer bars help prevent partial reads from sharp scan angles. Fixed length matters in practice: if every label has the same number of digits, a scan that skips or truncates part of the message is easy to reject.
The version most small businesses meet is ITF-14, which uses the same symbology for a 14-digit GTIN on cartons. GS1 US says it is used for cases and pallets, can print directly on corrugated board and is not used at retail point of sale. Our ITF-14 guide covers building and printing one. Plain Barcode's generator makes ITF-14, not general-length Interleaved 2 of 5.
Pharmacode
Pharmacode is unlike the others: it encodes one whole number from 3 to 131070 in binary, using narrow and wide bars. Seagull Scientific describes it as used in the packaging of pharmaceutical products, with a bar count of 2 to 16 and no check digit on the page.
It encodes only a small whole number, so it cannot carry a GTIN. The generator on this site does not make it. If a pharmaceutical customer or packaging line requires one, take the number and format from their specification, not from a general guide.
What to choose for new labels
Ask three questions in order:
- Does someone else require this symbology? If a customer, library, lab or legacy system names it, match it exactly, including the check digit and start/stop settings.
- Is it a carton for the supply chain? Use ITF-14, or GS1-128 when the label needs lot, date or shipment data.
- Is it a label your own team scans? Use Code 128. Mainstream scanners read it by default and it has a check character built in.
Support is the practical risk with older formats. Google's ML Kit, a common phone-scanning library, reads Codabar, Code 39, Code 93, Code 128, ITF and the retail formats, but its list does not include MSI or Pharmacode. A scanner that skips a symbology is often just configured that way, so if one will not read, see our not-scanning checklist.
Bottom line
You rarely need to choose one of these. Use them to match an existing system, and use Code 128 or ITF-14 for anything new. If you are unsure what a customer wants, get the symbology name, check digit method and size in writing before you print a run, and test a sample against their scanner. For the full decision by job, see which barcode type you need.
Sources
- Seagull Scientific (BarTender): Code 93 (accessed )
- Scandit: Code 93 (accessed )
- Seagull Scientific (BarTender): Codabar (accessed )
- Seagull Scientific (BarTender): Interleaved 2 of 5 (accessed )
- Standards Council of Canada: ISO/IEC 16390:2007 Interleaved 2 of 5 bar code symbology specification (accessed )
- DataFlex documentation: MSI Plessey - Barcode Type (accessed )
- Seagull Scientific (BarTender): PHARMA-CODE - One-Track (accessed )
- GS1 US: What is an ITF-14 Barcode? (accessed )
- Google for Developers: Barcode scanning (ML Kit) (accessed )
Newsletter
At most one e-mail a day, only about new guides and tools. No tracking pixels. How we handle your address